Operating sequence
Five steps during a wash cycle
- Water demand starts the system. When the washer opens its inlet valve, incoming cold-water flow activates the unit automatically.
- Incoming air passes through the desiccant dryer. The replaceable cartridge removes moisture from the air before it reaches the oxidation module; this is not an automatic dehumidification feature.
- The oxidation module produces ozone on demand. The module operates only while the unit detects the required water flow.
- Venturi injectors and the static mixer combine gas and water. The viewing window lets you check for bubbles and the normal blue operating light.
- Treated water flows to the washer. When water flow stops, the unit completes its short shutdown cycle and turns off automatically.

Inside an ozone laundry unit
This 6-minute film from Sihon Ozone shows an earlier laundry unit being opened on the workbench. Use it to see how the components fit inside. For service on your Eco3Wash, follow the instructions supplied with your model.
Product specifications
Key connection and size specifications
| Electrical input | AC 100-240V, 50/60Hz through the supplied adapter |
|---|---|
| Electrical output | DC 12V, 2.5A, 30W |
| Ozone concentration | 0.4-0.5 mg/L |
| Water pressure | 15-75 PSI |
| Water temperature | Cold water only |
| Dimensions | 432 x 254 x 94 mm |
| Net weight | 1.8 kg |
Product scope
Designed for residential laundry
What it is designed to do
Support cold-water laundry and help reduce reliance on detergent and hot-water use, depending on the load, washer, water quality, and cleaning needs.
What it is not
It is not a drinking-water device, a medical sterilizer, or a substitute for a validated healthcare or industrial laundry process.
Considering Eco3Wash for your product range?
Choose the distributor or OEM inquiry path to discuss the system for your market.